Mobile SVE/MPE Plant and Pilot Trial Unit
ERR Pilot Trial Unit
Application
- Pilot testing of site parameters as data needed for design of full scale in-situ remediation systems. Typical data includes:
- Radius of influence – vapour and groundwater
- Well yields – vapour, groundwater, PSH, vacuum
- VOC concentrations, dissolved contaminant concentrations in groundwater extracted under field conditions
- Temporary or final-stage remediation plant for small projects such as soil venting, soil vapour extraction (SVE) or multiphase extraction (MPE) systems. Treatment capacity for vapour and water streams can be increased if required
Features and Specifications
- Multiphase Vacuum Extraction (MPVE) and Soil Vapour Extraction (SVE) capability
- Vacuum blower (Roots), air dilution valve, vacuum relief valve
- Two GAC filter drums for removal of Volatile Organic Compounds (VOC’s) from vapour stream through
- Fluids-vapour separation in a conical cyclone type separator
- Liquids transfer tank with sight glass for observation of LNAPL. Three level control points for automated control of discharge pump
- Liquids transfer pump: automatic operation controlled by level sensors and PLC; manual speed control
- Data collection:
- Vacuum and pressure gauges
- Access points with gland seals for air flow measurement, thermometers or sampling
- Sampling points for vapour and liquids
- Sight glass on liquids transfer tank to observe PSH-water interface
- Volumetric flow meter (totaliser) on liquids discharge line
- Safety:
- ExE motors, wiring for Zone 2, include intrinsic barriers, earthing wire and stake
- System shut down at high level on liquids transfer tank
- Vacuum relieve valve (-60kPa), emergency stop button
- Handy toolbox: 1m long x 430mm wide x 400mm high
- Power requirements: 3 Phase 415V, 50Hz, 20Amps with neutral (5 pin). Minimum generator capacity required is 20kVA. 10 meter power lead and a phase rotation adaptor supplied with the unit
Quick Stats:
| Feature | Specs |
|---|---|
| Vacuum blower | Air flow 300m3/hour at -5kPa Vacuum to -60kPa ( 60m3/hour) (performance with exhaust stream through cooling system and GAC) |
| Liquids transfer pump | Max. pumping rate: 60 LPM |
| Vapour Treatment | 2 x Drums, approx 40L bed volume each |
| Power requirements | 3 Phase 415V, 50Hz, 20Amps with neutral (5 pin) Control Panel 240V |
User’s Advantage
- Reliable data taken under field conditions of a full scale remediation plant
- Operating capacities (vacuum and air flow) are suitable for pilot requirements of most sites
- Easy sampling of vapour and fluids
- Convenience of mobility (trailer mounted) when moving from site to site on short term and small scale soil venting, or MPVE or SVE applications
Ordering Information
| Available for Hire Daily/Weekly/Monthly | Other Options |
|---|---|
| Pilot Trial Unit Hire
PID Hire (optional) Hotwire Anemometer Hire (optional) IBC (1000 L) for storage of fluids |
Vapour treatment – filling and disposal of GAC for 2 drums (approx 30kg total)
Operator for running the unit (hourly) |