Vented Preassure Transducer
Application
Accurate monitoring and logging of changes in ground water level in wells and standpipes
Features and Specifications
- Converts pressure to a frequency signal
- Stainless Steel — dimensions: 29mm diameter, 191mm long
- Ranges, two models:
- -21kPa to 152kPa (-3psi to 22psi); or
- -21kPa to 345kPa (-3psi to 50psi)
- VW Minilogger stores 8000 data points
User’s Advantage
- Vented design eliminates influence on barometric pressure
- Thick vent tube 1/4″ diameter, prevents condensation and blockage
- Oversized desiccant chamber to prolong dry condition of vent tube
- VW Minilogger is simple to use and field ready — connect and go
Limitations
- Frequency signals are disrupted if transducer is deployed in the same well as an electric pump. This can be overcome by installing in a separate but adjacent well to the pump
Ordering Information
| Item No. | Description |
|---|---|
| 52612402 | Vented VW Pressure Transducer 22psi |
| 52612405 | Vented VW Pressure Transducer 50psi |
| 52614410 | Vented Cable (sold per metre) |
| 52612495 | Desiccant Chamber |
| 52614415 | Splice Kit for Vented Cable; includes components to splice conductors and vent tube |
| 52613310 | VW MiniLogger |